知识

>知识>内容

AE品牌便携式气体探测器的操作程序

2020年7月16日

AE品牌便携式气体探测器的操作程序

agh6100.

1.启动方法便携式燃气探测器:打开能量开关,便携式气体检测器进行预热自检。自检完成后,它会发出间歇性和有节奏的惊人声音;安装调整按钮,使左侧的第一个报警指示器是临界发光状态,同时存在间歇触发声,然后输入正常的工作状态。

2. How to use: Move the portable gas detector that has been zeroed close to the place needed to be detected, but don’t touch and hit the part, move slowly, if the continuous rhythm sound becomes rapid, and the number of LED lights on the display continues to increase, indicating that there is a gas leak. When the indicator light is on and the gas leakage has not been determined, then should adjust the knob in a counterclockwise direction, leaving only 1-2 indicator lights on, and continue to detect. The position of the probe is the gas leak point when the indicator lights up the most;

3.充电方法:关闭便携式气体检测器的电源开关,将充电器插入充电器插入仪器的充电插孔,并将充电器的电源插头插入220V电源插座。这是充电器上的红色指示灯,表明充电正常。当欠压指示灯接通时,这意味着电压太低,电池应及时充电,每次充电10-14小时

4.故障指示:开机后,显示屏左侧的第一个指示灯是电源指示灯,表示电池为空,需要充电,或电源不良好,您需要检查内部接线;与气体没有响应。如果灵敏度低,或者传感器失败,则需要重新校准或更换传感器;警报指示器接通,环境中存在气体,进一步确定泄漏点,或者将灵敏度调整为高电平,并且需要重新调整。

5.注意事项:

5.1注意轻轻地处理以避免有力的碰撞;

5.2非专业人士不应随便拆卸;

5.3探头严格禁止接触油和水等液体;

5.4严格禁止将大量气体引导到探针中;

5.5便携式气体检测器在未使用时每月充电一次,每次充电时间为10-14小时。